Set range: See parameter list
Accuracy: ±5%FS
Delay:Depend on the switch point , min. point 0.6L/Min
Pressure proof: 50bar(aluminum), 100bar( stainless steel)
Average pressure loss: 0.3bar( at 25L/min)
Medium temperature: Max.90 Celsius degree
Protective class: IP65
Application
Used for gas and liquid . Suitable for industrial automation / mechanical equipment/compressed air industry /refrigeration and air conditioning .
Feature
1,On-line installation 2,Mechanical type flow switch 3, Suitable for gas and liquid 4,Firm plastic, aluminum or stainless steel housing 5,Small pressure loss 6,Good repeatability and stain resistance 7,The mechanical part isolate from the electric part totally , it is economical type and suit for small flow range. 8, 3 times piston journey respond to original FE20 , which makes sure the high accuracy . 9, With switch setting scale ,so the used does not need to set in field . 10, LED display the switch state (option: double switch value output) .
Technical data
Set range: See parameter list
Accuracy: ±5%FS
Delay:Depend on the switch point , min. point 0.6L/Min
Switch set scale:Calibrate it under the horizontal installation for water medium (20 C) . Installation position : The medium and the temperature will Effect the switch value .
LED display: Display the switch state , if the LED is directly current supply .
It will no LED display for AC supply .
Connection:M12
Output:Reed switch, capacity 24VDC / 250VAC ,100mA
Pressure proof: 50bar(aluminum), 100bar( stainless steel)
Average pressure loss: 0.3bar( at 25L/min)
Medium temperature: Max.90 Celsius degree
Protective class: IP65
CX-FS-FE30…GA material: Housing: anode alumina
Piston: POM plastic
Reed switch: stainless steel
Seal: NBR
CX-FS-FE30…GK material : Housing: stainless steel
Piston: POM plastic
Reed switch: stainless steel
Seal: NBR
Type |
Pressure Bar |
Max.flow rate L/min(water) |
Adjustable range L/min(water) |
G mm |
L mm |
H mm |
B mm |
X mm |
weight Kg |
CX-FS-FE30-020…A(K)070… 50(100) 100 27(21)…70(66) G3/4 105 36 35 15 0.23(0.65)
CX-FS-FE30-025…A(K)070… 50(100) 100 27(21)…70(66) G1 105 36 40 15 0.32(0.82)
Note :
1, The parameter in bracket is reset point, the parameter outside the bracket is action point .If the lower limit alarm (the monitoring flow rate is too small) ,at the time reference the reset parameter . If the upper limit alarm (the monitoring flow rate is too big) , then reference the action parameter .
2, Under vertically installing on horizontal pipe , then test to get the above parameter for 20 Celsius degree water..
CX-FS-FE30- | 025 | G | D | L | 070 | M | 1 | |
CX-FS-FE30- | CXFE30 series piston flow switch | |||||||
020 | G3/4 | |||||||
025 | G1 | |||||||
G | Female screw | |||||||
D | DC 24V±20%DC | |||||||
J | AC 230V±15%AC | |||||||
S | Plastic housing | |||||||
L | Anode alumina housing | |||||||
X | Stainless steel housing | |||||||
070 | Set range :27…70L/min | |||||||
M | M12 | |||||||
Z | Direct cable | |||||||
1 | 1 switch point output | |||||||
2 | 2 witches point output |
ZL04- | PU | 02 | M | Z | description |
ZL04- | M12 4-core connector | ||||
SL04- | M12 | ||||
PU | PUR | ||||
02 | 2m | ||||
05 | 5m | ||||
10 | 10m | ||||
M | Female plug | ||||
Z | Direct type | ||||
W | Bend type |
Contact:Leon
Tel: +86021-57635022
Email:info@cxflowmeter.com
Add:Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)