Sewage Clamp-On Flow Meter
Email: sales01@cxflowmeter.com
WhatsApp: 008618049841995
Sewage Clamp-On Flow Meter
Today, a customer requested two clamp-on flow meters and provided the following information:
1.1 Measuring medium: Water, seawater, sewage, and other uniform, single, stable liquids.
1.2 Medium temperature range: -30°C to 150°C (some models can reach -40°C to 160°C).
1.3 Measurement accuracy: ±1.0%
1.4 Applicable pipe diameter: DN15mm to DN6000mm.
1.5 Flow rate range: 0 to ±32m/s (bidirectional flow).
1.6 Output methods: 4-20mA, RS232/RS485 communication, pulse signal, relay output, etc. Input signal: Supports multiple 4-20mA signal inputs (such as temperature, pressure, liquid level, etc.).
1.7 Power supply: AC220V.
1.8 Protection rating: IP68 (submersible to a depth of ≤3 meters).
1.9 Installation Requirements: Straight pipe length: Upstream ≥ 10D, downstream ≥ 5D, ≥ 30D from the pump outlet (D is the pipe diameter).
1.10 Installation Method: Clamp-on installation, no pipe damage required, suitable for pipes made of steel, stainless steel, cast iron, PVC, copper, aluminum, fiberglass, and other materials.
After analysis, our technicians recommended our wall-mounted ultrasonic flowmeter.
Wall-mounted ultrasonic flowmeter
Diameters range from 15 to 1000DN. For short-term temperatures, 150 to 160°C is acceptable, while for longer-term temperatures, 120 to 130°C is acceptable.
High-temperature type
For sewage, impurities should not exceed 5%. For seawater, regular pipe cleaning is recommended.
The output is 10-20mA, and it supports pulses with a 485 relay.
304 stainless steel is acceptable, but 316 and copper are not.
It is compatible with small, medium, and large sensors.
If you have any questions about water, seawater, or sewage flow meter selection and pricing, please contact CIXIFM Winny:
Email: sales01@cxflowmeter.com
WhatsApp: 008618049841995