Asphalt Pump Selection
Email: sales01@cxflowmeter.com
WhatsApp: 008618049841995
Asphalt Pump Selection
We require a three-phase AC power supply.
Voltage: 380–400 V (star connection) / 660 V (delta connection) (assuming 380 V).
Frequency: 50 Hz.
Ingress Protection: IP55 or higher.
Suitable for asphalt pump operating environments (maximum ambient temperature 45°C, pumped medium temperature 140–160°C).
Gear-type asphalt pump, quantity 1 unit.
Asphalt viscosity 76 centistokes, temperature 140–160°C, flow rate 208 cubic meters/hour, pressure 0.81 MPa.
After receiving the inquiry, our technicians recommended the KCB3800 gear pump.
KCB3800 Gear Pump
Media: Asphalt
Viscosity: 76 cSt
Flow Rate: 208 m³/h
Discharge Pressure: 0.6 MPa
Power: 160 kW-6P explosion-proof motor BT4
Power Supply: AC 380V 50Hz 3PH
Diameter: 250/250 flange
Seal: Packing seal
Wetted Material: HT200 with pump head insulation
Media Temperature: 140-160°C
If you have specific asphalt pump selection and quote requirements, please contact CIXIFM Winny: