Introduction
Thermal Type Gas Mass Flowmeter utilizes the principle of heat exchange to measure fluid-flow. This meter employs method of constant temperature difference to accurately measure gas mass flow, and it has the advantages of small size, high degree of digitization, easy installation, accurate measurement, etc.
The sensor part consists of two platinum resistance converters of reference level. It utilizes bridge type loop circuit, with one converter measuring fluid temperature, and another maintaining constant temperature difference that is higher than fluid temperature. The measurement can be made under high temperature and high pressure situation.
Advantages
It is a true mass flowmeter that can conveniently and accurately measure gas-flow rate without temperature and pressure compensation, from which users can get gas mass flow or standard volume flow.
Large ratio of measuring range. It can measure gas with velocity of flow from 100Nm/s to 0.5Nm/s, and be used in gas leak hunting.
Good anti-seismic performance and long useful life. The converter doesn’t contain movable part and pressure sense part, so that the measuring accuracy will not be influenced by shaking.
Easy installation and maintenance. If possible, on line installations and maintenance are allowed. (See Safety Notice)
Digital design. The meter utilizes digital circuit measurement to assure accurate result and convenient maintenance.
Factory automation and integration can be achieved by using RS-485 or HART communication.
[Parameters]
Production Name |
High Quality 1.0% Precision SS316L Thermal Gas Mass Flow Meter |
Medium |
all kinds of gas |
Diameter |
DN20~DN2000 |
Flow rate |
0.5~100Nm/s |
Accuracy |
1.0%;1.5% |
Temperature |
Sensor:Ambient temperature:-10~200℃ |
|
Max temperature:10~350℃ |
|
converter: 10~45℃ |
Pressure |
Medium pressure≤4.0Mpa |
Power supply |
Integrated:DC24V or AC220V≤180W |
|
Splited:AC220V≤19W |
Feedback speed |
1s |
Output |
Standard output:4~20mA;Can customized for RS485 |
Material |
Stainless steel 304 material |
Display |
LCD Display |
Display |
mass flow;volume flow;total flow;time;temperature;standard flow. |
Protection class |
IP67 |
Converter material |
stainless steel material |
1.Flow range
Item |
The thermal mass flow meter flow range table |
Diameter |
Flow range (Nm3/h) |
DN20 |
1.2~120 |
DN25 |
2.5~168.5 |
DN32 |
4~275 |
DN40 |
6~430 |
DN50 |
9~671.5 |
DN80 |
20~1718.5 |
DN100 |
30~2685 |
DN150 |
60~6045 |
DN150 |
60~6045(plug-in) |
DN200 |
120~12738.5(plug-in) |
DN250 |
150~18779(plug-in) |
DN300 |
200~28000(plug-in) |
DN400 |
350~48955.5(plug-in) |
DN500 |
600~77177.5(plug-in) |
DN600 |
800~100000(plug-in) |
Installation And Connection
If installed outside, the meter should be covered by sky shade to avoid exposing to the sun and rain.
Do not install in sharp pounding situation.
Do not expose to dangerous environment heavily charged with corrosive gas.
Do not share power source with polluting equipment such as converter and welding machine,
and power conditioner can be installed for converter if necessary.
Installations and Connection of All-in-one Meter
Exterior Appearance Construction Drawing
All-in-one plug type should be inserted in axes of the measured pipeline; therefore,
the length of overcastting staff depends on the caliber of the measured pipeline. If impossible,
the manufacture will offer calibration coefficient to accomplish accurate measurement.
All-in-one full-tube type employs flanged connection, in accordance with GB/T9119-2000(details see appendix 2).
Contact:Leon
Tel: +86021-57635022
Email:info@cxflowmeter.com
Add:Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)