Welcome: Shanghai cixi instrument CO.,LTD,it's a professional 35 years manufacturer of micro flow meter,ultrasonic flow meter,water flow meter,magnetic flow meter,turbine flow meter,vortex flow meter,coriolis flow meter,digital flow meter,thermal mass flow meter,liquid flow meter,gas flow meter,dosing pump,gear metering pump,level transmitter,level sensor etc.
Home > Products > Flow Meter > Wet Gas Flow meter >

wet gas flow meter

wet gas flow meter

  •     At a confidence probability of 0.95, the expanded uncertainty is 0.2%, 0.5%

        Does not require strict temperature, can be used at room temperature

        Intuitive readings, easy to use

        Made of stainless steel or preservative-treated material for long life.
     

    INQUIRY

    Measuring Medium

    XML type is normal-type, it adopts brass material, and generally used in the scope of non-corrosive gases.

    XMF type is anticorrosive-type, it adopts stainless steel material, can measure corrosive gases.
 

   Parameters

 Parameters-Wet gas meter
 Model  LML/F;BSD/BSDF
 Medium  Various gas
 Rated flow  200;500
 Total flow  999999
 Overload flow  300;750
 Pressure  10000pa
 Accuracy  1.0%
 Weight  4.5~6.0kg
 Min scale  0.008;0.02L
 Diameter  266*220*335;310*220*335


    Usage

    1. Put the meter on the worktable, adjust screws to enable blister of leveler in the centre, and maintain for a long time in use.

    2. Open sealed screw cap of water level controller, pull out internal wool rope.

    3. In the plug jack of thermometer or manometer, inject distilled water into the meter, when redundant distilled water drain from hole of water level controller ( sometimes it is clean when outflow one drop), then put wool rope in sealed screw cap of water level controller, and fasten the sealed screw cap.

    4. Install thermometer and manometer, (every case 10Pa)

    5. Connect air channel according to direction of gas outlet and intake, and sealled.

    6. Open gas valve, and then you can measure gas.
 

    Attentions While Using

    1. When you use it, you must always pay attention to the water level in the meter, otherwise it will affect measuring accuracy.

    2. When you use it, temperature should be maintained at 15 ~ 25 ℃, and the temperature is the same as room temperature, its temperature difference should be ≤ 2 ℃.

    3. You’d better readout in a few weeks after the operation of the meter.

    4. When pressure of measuring gas is go beyond normal pressure 1 ~ 6 times (1 ~ 6 KPa), the meters can still work, at this time manometer should be removed , then use rubber plug plugs up mounting holes of manometer.

    5. When flow of measuring gas is go beyond rated flow, the meters can still work, but measuring accuracy will be greatly decreased.

    7. The meter should not be installed in a cold room, for fear that it will freeze inside.

    8. In normal circumstances, check out accuracy every year at least.

Previous:None Next:None