CX-RLM-080 series of intelligentradar substance position gauge |
|
|
|
Types | CX-RLM-081 | CX-RLM-082 | CX-RLM-083 |
Application |
Process condition is simple, corrosive liquids, slurries and solids For example: Water tank Acid and alkali tanks Slurry tanks Solid granules Small petrol tanks |
Storing corrosive liquids, slurries and solids For example: Water tank Acid and alkali tanks Slurry tanks Solid granules Small petrol tanks |
Suitable for all kinds of storing tanks or process measuring environment, liquids, slurries and solids. For example: Crude oil, light oil tank Coal and powder coal bunkers Volatile liquid tank Charcoal level Slurry tank Solid granules |
Measuring range | 20 meters | 20 meters | 35 meters |
Process connection | Screw | Flange | Flange |
Process temperature | -40-130℃ | -40-150℃ | -40-250℃ |
Process pressure | -1.0-3bar | -1.0-20bar | -1.0-40bar |
Repeatability | ± 3mm | ± 3mm | ± 3mm |
Precision | < 0.1% | < 0.1% | < 0.1% |
Frequency range | 6.8GHz | 6.8GHz | 6.8GHz |
Anti-explosion/ safety grade |
EXiaIICT6/IP68 | EXiaIICT6/IP68 | EXiaIICT6/IP68 |
Signal output |
4…20mA/HART (two phases) |
4…20mA/HART (two phases) |
4…20mA/HART (two phases) |
Contact:Leon
Tel: +86021-57635022
Email:info@cxflowmeter.com
Add:Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)