Welcome: Shanghai cixi instrument CO.,LTD,it's a professional 35 years manufacturer of micro flow meter,ultrasonic flow meter,water flow meter,magnetic flow meter,turbine flow meter,vortex flow meter,coriolis flow meter,digital flow meter,thermal mass flow meter,liquid flow meter,gas flow meter,dosing pump,gear metering pump,level transmitter,level sensor etc.

Industry News

Home > News > Industry News >

Selection of water, acetic acid, hydrogen peroxide liquid metering pump


Email: sales01@cxflowmeter.com
whatsapp: 008618049841995
 
Selection of water, acetic acid, hydrogen peroxide and peracetic acid metering pump
 
Today, a customer inquired about the selection of water (35%) + acetic acid (25%) + hydrogen peroxide (25%) + peracetic acid (15%) mixture chemical liquid metering pump
 
He provided the following detailed information:
 
Medium: water (35%) + acetic acid (25%) + hydrogen peroxide (25%) + peracetic acid (15%)
 
Flow rate: 2-20ml/m at the beginning, up to 50ml/m at room temperature
 
Outlet pressure is up to 3bar, usually 1-2bar
 
With stepper motor

 
After analysis by our technicians, the following recommended information was given:
Recommended 0.15CC magnetic pump, material 316+PEEK, this material should be confirmed with the customer whether it is resistant to his medium.
 
It is not recommended to match the motor with a stepper, and it is best to choose a servo with pressure. If you must choose a stepper motor, then choose a 0.3CC pump head.
 
If you also encounter specific chemical liquid pump selection and quotation issues, please consult CIXIFM winny:
Email: sales01@cxflowmeter.com
whatsapp: 008618049841995




 
Previous:Selection of magnetic level gauge Next:None