Micro oval gear flow meter used on mixed polymer containing alcohol chloroform hydrochloric acid
sales01@cxflowmeter.com
Receiving a consultation from a customer, he needs to use the
micro flow meter to measure the mixed polymer containing alcohol, chloroform,
hydrochloric acid and other substances. Since the viscosity of the medium will increase at low temperature and even solidify, the customer chooses
to use a hot water pad to heat the flow meter, so that it can ensure the normal circulation of the medium in the flow meter.
The customer provides the following parameters
A:
Medium: Chloroform-containing polymer solution
Need to be resistant to chloroform and hydrochloric acid
Flow: 2~10ml/min
Polymer viscosity: 700 Poise (70000cp)
Temperature: 57~63℃
Pressure: < 10 bar
Output: 4~20mA
Explosion-proof
the
b.
Medium: bore-liquid (alcohol components such as methanol, ethanol, chloroform, trichloroethylene, etc.)
Need to be resistant to chloroform and hydrochloric acid
Flow: max 10ml/min
Viscosity: 0.5~1.8CP
Temperature: 20 - 60℃
Pressure: < 4 bar
Output: 4~20mA
Explosion-proof
the
c.
Medium: Chloroform-containing polymer solution
Need to be resistant to chloroform and hydrochloric acid
Flow: 200l/h
Viscosity of polymer solution: 70000 ~110000cp
Temperature: 35 ~ 65℃
Pressure: < 5 bar
Output: 4~20mA
Explosion-proof
We suggest that customer use remote display. Flow meter with DC8S remote digital display.
the
The flowmeter is explosion-proof with Hessman joint glue filling.
Flowmeters with filling glue explosion-proof, customer need to prepare an explosion-proof box for digital display, so that the whole explosion-proof.
If you want to know more about the selection and quotation of chemical precision flowmeters, please contact winny: sales01@cxflowmeter.com