Natural gas flowmeter, widely used in petroleum, chemical, electric power, metallurgy, urban gas supply and other industries to measure various gas flow, is currently the oil field and urban natural gas transmission and distribution measurement and trade measurement of the preferred product.
Natural gas flowmeter parameters
Caliber: DN15 ~ DN3000mm
Nominal pressure: 0.6 ~ 42MPa
Operating temperature: -180 ~ +500℃
Accuracy of natural gas flowmeter: ±0.2 ~ ±1.5%FS
Range ratio: 1:10
Shell: carbon steel;Stainless steel (or as required)(fluorine lined)
Power supply mode of natural gas flowmeter: built-in 3.6VDC lithium battery (change every two years);External supply 24VDC (optional)
Output signal of natural gas flowmeter: 4-20ma two-wire system;Pulse 0 ~ 1000HZ;RS232/RS485(or as required by the user)
Protection grade: IP65IP67
Explosion-proof mark: intrinsically safe ExiallCT4;Flameproof ExdllCT4
Executive standard: enterprise standard Q/ bet05-06
Table head: cumulative flow;Instantaneous flow rate;Operating temperature;Operating pressure (temperature and pressure compensation);Percentage of bar full range;Breakdown self check
Nominal size: clamping type: DN10 ~ DN300;Insertion: DN350 ~ DN1000;Flanged: DN10 ~ DN300.
Main advantages of natural gas flowmeter:
1, natural gas flowmeter without mechanical movable parts, corrosion resistant, stable and reliable, long life, long-term operation without special maintenance;
2. Natural gas flowmeter realizes mechatronics, and daily metering process does not need manual operation;
3. The process installation conditions of natural gas flowmeter are not harsh, and the upper and lower straight pipe sections of the meter can be greatly shortened compared with orifice and vortex street flowmeters;
4. The measurement accuracy of the natural gas flowmeter system can meet the current trade measurement requirements (≤1.5%);
5. The measuring range of natural gas flowmeter is wide (qmax/qmin=15 ~ 20), and it can work effectively in some small flow areas that cannot be penetrated by orifice plate and vortex street flowmeter;
6. Small size, light weight, convenient off-line calibration;
7. The measurement signal can be displayed locally or transmitted far as needed;
8. There is no need for professional training for instrument management personnel, and measurement parameters such as flow, pressure and temperature can be read directly from the meter head without conversion;
9. You only need to change the parameters of the battery (micro-power consumption) and the tested medium regularly.
10. Large pressure loss of natural gas flowmeter;
When the flow medium is gas, the pressure loss is about 3 ~ 4 times of that of vortex flowmeter.
Contact:Leon
Tel: +86021-57635022
Email:info@cxflowmeter.com
Add:Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)