Welcome: Shanghai cixi instrument CO.,LTD,it's a professional 35 years manufacturer of micro flow meter,ultrasonic flow meter,water flow meter,magnetic flow meter,turbine flow meter,vortex flow meter,coriolis flow meter,digital flow meter,thermal mass flow meter,liquid flow meter,gas flow meter,dosing pump,gear metering pump,level transmitter,level sensor etc.

Industry News

Home > News > Industry News >

Liquid flow display instrument, liquid flowmeter measurement what are the requirements

Liquid flow meter, liquid flow meter based on Faraday electromagnetic induction principle developed a measurement of conductive liquid volume flow meter, for the liquid flow meter measurement requirements do you know?Ask letter small today with you to understand the liquid flowmeter measurement matters needing attention.

Liquid flow display instrument,

Key points of liquid flowmeter selection:

 

Installation: there are three general installation methods, flange type, clamping type and insertion type. According to the actual working conditions of the site, what installation method should be chosen? These three installation methods will not be affected by the working conditions of the site.

 

Electrode form: general electrode form has three kinds, can be divided into standard fixed type, scraper type, detachable type.

 

Electrode material: in the electromagnetic flowmeter, the commonly used electrode materials are: stainless steel 316L, HB, HC, Ti, Ta, Pt Pt, tungsten carbide WC, etc., which need to be determined according to the measurement medium.

 

Nominal size: commonly used are DN10, DN15, DN32, DN40, DN50, DN65, etc., which are determined according to the flow range and the working conditions on site.

 

1. The measured liquid medium in the pipe must be full.Only when the measured medium is in full tube state, can the above several flowmeters work normally, if it is in non-full tube state, even if the meter can work, the measurement result deviation will be relatively large.

 

2. The tested liquid medium should be relatively clean.Generally speaking, the liquid flowmeter cannot be interfered by a large number of impurities or sundry when measuring, especially the ultrasonic flowmeter, if it encounters a large piece of impurities, it will affect the sound wave transmission, thus affecting the measurement.Electromagnetic flowmeters can also be blocked by large chunks of dirt, which can interfere with measurements.If the turbine flowmeter encounters large debris, it will not only affect the measurement accuracy, but also damage the instrument.Therefore, it is better to install a filter upstream.

 

3. The medium using electromagnetic flowmeter must be conductive, and the medium using ultrasonic flowmeter must be able to conduct sound. It is recommended to choose turbine flowmeter for medium measurement of small flow.

 

4. Requirements of using environment.Generally speaking, the liquid flowmeter in the measurement of the need to avoid strong magnetic field and other interference sources, to try to stay away from the pump, valve, elbow and other special pipe section area.

 

5. Requirements for straight pipe section.The liquid flowmeter shall be installed at least 10 times the upstream pipe diameter and 5 times the downstream pipe diameter.