Selection of natural gas odorizing metering pump
Email:sales01@cxflowmeter.com whatsapp:008618049841995
Natural gas odorizing
metering pump
Today, I received a customer's inquiry about electromagnetic diaphragm metering pump for natural gas odorization
The customer provided the following information:
Medium: odorization Pressure 3.2-3.6MPa, hourly flow rate not less than 0.5L/H, room temperature
Pump head is made of stainless steel, and the motor is explosion-proof
Odorizing device parameter table:
Natural gas flow rate 6293~21780Nm3/h
Dosing concentration: 20mg/Nm3
Odorizing point operating pressure: 3.2~3.6MPA
Odorizing point design pressure: 4.0Mpa
Odorizing tank volume 60L
After analysis by our technicians, the technicians said:
Electromagnetic diaphragm metering pumps cannot produce such high pressures, and conventionally they are within 8 kg
It is recommended that customers use plunger metering pumps
CX-J1-2/3.6
Flow rate 2L/H
Pressure 3.6MPA
Motor power 0.37KW-4 explosion-proof motor
Pump head material 304 stainless steel
Inlet and outlet are DN15 union connection
If you are currently facing the trouble of
dosing pump metering pump selection, please consult CIXIFM winny:
Email:sales01@cxflowmeter.com whatsapp:008618049841995