Today, we received a consultation from a customer who needed an
air flow meter but didn't know how to choose one. He provided the following technical requirements:
1) Working medium: normal temperature air;
2) Diameter: DN80;
3) Measuring range: 250Nm3/h~6000Nm3/h;
4) Working pressure: ~3.5MPa;
5) Material: 316L;
6) Structural accessories: with butt-jointed flanges, gaskets and fasteners;
7) Electronic control accessories: local display, remote transmitter, electronic control accessories, cables, etc.;
The customer doesn't know whether to choose a turbine or a vortex street? Or other types of flow meters are suitable, and it is difficult to modify the on-site pipeline.
After we converted it to 8-166m³/h, it is recommended to use a DN50/65 caliber
gas turbine flow meter, and the customer can match a conversion head by himself.