R134a R410 Refrigerant Magnetic Pump Selection
Today, a customer needs to select a suitable conveying metering pump magnetic pump for refrigerant quantitative filling
Here are the detailed information provided by the customer:
Medium:
The viscosity of R134a is (25℃)/Pa.s liquid 0.202cps
The viscosity of R410 is (25℃)/Pa.s liquid 0.12cps
Flow range: nominal 68 GPH at 3500 RPM, equivalent to 4284 ml/min
12v brushed motor
Working pressure: 6.89bar
Outlet pressure: Maximum 12.07bar
Flow range: 3150-4725ml/min
The viscosity of the liquid is super low, he wants to know if our magnetic pump can meet his needs?
After analysis, our technicians recommended our
Magnetic pump CX-1.5-72-170W DC brushless built-in drive motor
If you are also troubled by the selection of
precision metering pumps and don’t know how to choose and the price, please consult CIXIFM winny:
Email: sales01@cxflowmeter.com