Welcome: Shanghai cixi instrument CO.,LTD,it's a professional 35 years manufacturer of micro flow meter,ultrasonic flow meter,water flow meter,magnetic flow meter,turbine flow meter,vortex flow meter,coriolis flow meter,digital flow meter,thermal mass flow meter,liquid flow meter,gas flow meter,dosing pump,gear metering pump,level transmitter,level sensor etc.

INDUSTRIAL

Home > Application > INDUSTRIAL >

Papermaking additive liquid enzyme flow meter

sales01@cxflowmeter.com


Today, a customer asked what kind of flow meter should be used to monitor and control the mixing ratio of enzyme and water?
 
So today CIXIFM winny will work with you to analyze based on the actual situation of this customer.
 
 
1. Working conditions:
Medium: enzyme mixed with water
Viscosity: slightly thicker than water
Flow: 5-300ml/min
Temperature and pressure: normal temperature and pressure
Power source: rotor pump
Detection method: Traffic monitoring
Display: Digital display meter needs to be configured. Real-time monitoring of traffic + alarm signals
Specific working conditions: The customer is using it in a paper mill, and papermaking needs to add enzyme liquid. Enzyme is mixed with water, and the amount of enzyme added requires precise measurement and control.
 
2. Industry analysis:
1. Why use a flow meter:
Because the addition of chemical enzymes is very important to the quality of the paper produced, whether the color of the paper is authentic, whether the thickness of the paper is uniform, whether the amount of dust
is present, whether the corners are neat, etc. are closely related to the amount of this enzyme added. inseparable relationship.
 
2. Disadvantages of not using a flow meter:
           The customer used to pour the corresponding amount of enzyme based on manual experience, but because the amount added is relatively small, the judgment with the naked eye is not
so accurate. After the product comes out, there will be a lot of defective products, which are mainly manifested in uneven paper thickness, serious dust content, and high scrap rate. This seriously
affected the delivery time promised by the factory to customers, and also resulted in the loss of many orders, and the cost was not well controlled. With the addition of the function of our flow
meter and alarm signal, we can detect the amount of addition in time. We can judge the amount of addition in a timely and accurate manner.
 
 
 
 
If you want to know more about the selection and quotation of precision flow proportioning flow meter, please feel free to contact CIXIFM winny: sales01@cxflowmeter.com








 

PRODUCTS

CATEGORIES

CONTACT US

Contact:Leon

Tel: +86021-57635022

Email:info@cxflowmeter.com

Add:Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)