Differential pressure transmitter selection
Email:sales01@cxflowmeter.com
whatsapp:008618049841995
Today, we received an inquiry from a customer who needs to purchase a
differential pressure transmitter.
He provided the following information:
Range: 2000 PSI, 0-200" WC calibration, 0-400" WC
Output 4-20MA + HART
Power supply rating: 24VDC
Size/connection: 1/2" FNPT with adapter
Explosion-proof level: E EXD IIC, E EXIA
IP identification: IP66, 67
2-wire loop power supply
Electrical connection: 1/2" NPTF
Body/flange material: CU-AI/316SS
Diaphragm/wetted parts: HASTALOY C/316SS
Filling fluid material: Silicone
Turndown ratio: 40 to 1
Stability: -+0.015% URL
Accuracy: -+0.075% URL
Humidity: 0-95% RH -10- 60 C
5-way SS Manifold
Local display must be configurable in engineering units
Mounting bracket 2 inches
Configurable: HART
Technician reply:
1. It can meet the explosion-proof level, but the certificate cannot be provided,
2. The filling medium is silicone oil,
3. The range ratio is 100:1,
4. Stability 0.25%,
5. Accuracy 0.075%,
6. Ask the customer what it means that the local display must be configurable in engineering units. The display unit of the product itself can be adjusted,
7. There are three ranges, let the customer confirm which one to choose
8. The protection level is IP65
There is no problem with the other parameters. After confirming the above with the customer, if the customer thinks it is okay, CX-PT-3051A-4/H-D-40Mpa can be used, and it can also be equipped with 316 five-group valve.
Email:sales01@cxflowmeter.com
whatsapp:008618049841995